Need Help? Talk to a specialist: 1-630-543-3747

WiFi Vaccine Temperature Data Logger

This product has been replaced by the DWE

DicksonOne automatically collects temperature and humidity data and delivers it to where you are. Easily set alarms and track trends without wasting time collecting charts or downloading data.  Let DicksonOne be proactive about your data so you don’t have to!

DicksonOne Features:

  • Access your data from any internet connected device, anywhere!
  • Multiple locations - monitor 1 point or 1000's
  • Scaleable to any number of loggers
  • Easy-to-use interface
  • Email & SMS Text Alerts
  • Secure Data
  • Select Models are RS compatible

Note: DicksonOne Data Loggers require a DicksonOne subscription to function correctly.

To view more about the DicksonOne platform visit: DicksonOne.com

Wft22 glycol straight on 12474
Default
R800 probe 12460
Wfh20 w r800 probe left angle 12461
Wfh20 w r800 probe rt angle 12462

Download Images: Print Quality | Hi-Res


Dickson Expert Services

Our Dickson Data Division has specially trained representatives to address the needs of customers with large installations or unique demands. Please call 888-452-4626.

Similar Products

TWE

TWP
Description Touchscreen Logger - WiFi/Ethernet Touchscreen - Power over Ethernet, WiFi / Ethernet
Price $524.00 $599.00
Remote Probe Icon compare check Icon compare check
Alarms
  • Audible
  • Text/SMS
  • Visual
  • Phone
  • Email
  • Audible
  • Text/SMS
  • Visual
  • Phone
  • Email
DicksonOne Compatible
Icon question
Icon compare check Icon compare check
Compare Compare
Add to Cart Add to Cart
  • Alarm Type Phone Call, SMS Text, Email, Audible
  • Ambient Operating RH Conditions 0-95% RH non-condensing (Logger only)
  • Ambient Operating Temperature Conditions -22 to 160F (-30 to 71C)
  • Antenna Type External
  • Approvals RoHS, FCC Part 15 Compliance, CE
  • Battery Backup 4 AA Batteries
  • Battery Life (Avg) 72 hours
  • Calibration Options N100 , N300, N400, & N520
  • Channels CH1: Temperature, CH2: Temperature
  • Data Capacity 32,000 (16,000 per channel); Backup
  • Digital Display Yes
  • Dimensions 1.7 x 4.25 x 4.25in
  • Download Type Wireless
  • Enclosure Black; ABS Plastic Clam Shell
  • IP Rating 21
  • Included Accessories USB Cable, AC Adapter, 2-Probe with Glycol Bottle, 4 AA Batteries
  • Mounting Options Free Standing or Wall Mount (With Keyhole)
  • Note on Alarm Type Alarms can be created for scenarios where the readings are outside a given range, communication has been lost, or the batteries are low. All paid accounts are eligible to receive email and SMS text alarm notifications.
  • PC Requirements HelpMinimum of 2 GB RAM; Windows XP (with service pack 3) and Windows 7; 2 available USB ports
  • Power Cord 6 ft
  • Power Source 120 to 240 VAC, 12 VDC (INTL fittings available)
  • Power Source Input AC 100-240 0.5V 60/50 Hz
  • Power Source Output DC 9V, 1A
  • Power Status Indicator Red/Green/Blue (RGB) LED
  • Radio Frequency 2.4 GHZ
  • Remote Sensor Length 6 ft (up to 3 extension cables can be added without sacrificing accuracy)
  • Response Time 30 Seconds to 63% of Full Scale
  • Sample Interval User Selectable from: 60 seconds, 90 seconds, 2 minutes, 5 minutes, 10 minutes, 30 minutes, 1 hour
  • Software Options All DicksonOne Data Loggers must be connected to a DicksonOne subscription to function correctly.
  • Storage Conditions -22 to 158F (-30 to 70C)
  • Storage Conditions RH 0-95% RH non-condensing
  • Temperature Accuracy +/-0.9F from -58 to 68F (+/-0.5C from -50 to 20C); +/-1.2F from 69 to 122F (+/-0.7C from 21 to 50C)
  • Temperature Accuracy (Remainder of Range) +/-1.8F (+/-1C) from 123-158F (51-70C)
  • Temperature Range Help-58 to 158F (-50 to 70C)
  • Temperature Sensor Type Field Replaceable Thermistor hard wired to PBC, submersible tip sealed in leak-proof glycol bottle Glycol will freeze at -55F
  • Unit Weight 3 lbs
  • Units/Pkg 1
Why should I calibrate?

All instruments lose accuracy over time due to normal usage and the environmental conditions to which they are exposed.

How often should I calibrate?

For most applications, the recommended calibration interval is every twelve months.

N100 1-Point NIST Traceable Calibration $99.00 Add
N300 3-Point NIST Traceable Calibration $156.00 Add
N400 3-Point Ultima NIST A2LA Accredited Calibration $269.00 Add
What is NIST Calibration?

NIST stands for the National Institute for Standards and Technology. This organization is responsible for maintaining the master for different measurements, such as the standard "foot", standard, "second", or standard "pound". NIST also maintains the standard for temperature, humidity and pressure.

NIST Traceable means that the measuring standard can be traced directly back to the master standard maintained by the NIST organization.

NIST-Traceable does not tell you the measurement accuracy of a metrologty service in any detail. Only metrology services that can document their ISO 17025 standard provided data on their best measurement uncertainty.

$110.00
Replaceable Sensor

Dual Thermistor Replaceable Temperature Sensor

$420.00
DicksonOne IQOQ Validation Checklist

DicksonOne IQOQ Validation Checklist

$32.00
Glass Beads Bottle

Bottle of Glass Bead Solution - Dampen Temperature Swings.

$32.00
AC Adapter

AC Adapter

$32.00
Universal Plug Kit for AC Adapter

Set of Three International Power Plugs for AC Adapter