Need Help? Talk to a specialist: 1-630-543-3747

8" (203mm) Temperature Chart Recorder

The reliable, valuable, and dependable Chart Recorder you've come to know and love from Dickson . . . now equipped with a Replaceable Sensor.

  • 8" Chart (203mm)
  • Replaceable Sensor
  • K-Thermocouple Probe
  • AC Power (With Battery Back-Up)
  • User selectable recording times and temperature ranges

For use above 500F (260C) A203 required.

  • Note: 31 Day chart is not available for temperature ranges [-20 to 20] and [0 to 150]
Calibration Method

Calibration ensures Regulatory and Audit Compliance

KT8P2
$489.00
Kt8p2 straight on 12390
R400 probe 12348
Kt8p2 left angle 12388
Kt8p2 rt angle 12389
Kt8p2 straight on open no chart 12395
Kt8p2 straight on open w chart 12396
Kt8p2 left side 12393
Kt8p2 rt side 12394
Kt8p2 back closed 12391
Kt8p2 back open 12392

Download Images: Print Quality | Hi-Res


Important Information

Charts are sold separately.

Dickson Expert Services

Our Dickson Data Division has specially trained representatives to address the needs of customers with large installations or unique demands. Please call 888-452-4626.

Similar Products

KT856

TSB

TWE
Description 8" (203mm) Temperature Chart Recorder with Probe, Display, Alarm and Relays Touchscreen Logger with USB Download Touchscreen Logger - WiFi/Ethernet
Price $759.00 $424.00 $524.00
Remote Probe Icon compare check Icon compare check Icon compare check
Relay Icon compare check
Alarms
  • Audible
  • Visual
  • Audible
  • Visual
  • Audible
  • Text/SMS
  • Visual
  • Phone
  • Email
Temperature Range Icon question
  • -50 to 50F/C
  • -20 to 20F/C
  • 0 to 100F/C
  • 0 to 150F/C
  • 0 to 250F/C
  • 0 to 500F
  • 0 to 1000F/C
  • 0 to 2000F
  • 20 to 100F/C
  • 50 to 150F/C
Temperature Accuracy
  • +/-1.8F from -22 to 122F 3.8F Remaining
    (+/-1C from -30 to 50C 2.1C Remaining)
DicksonOne Compatible
Icon question
Icon compare check
Compare Compare Compare
Add to Cart Add to Cart Add to Cart
  • Ambient Operating RH Conditions 0-95% RH non-condensing (Recorder Only)
  • Ambient Operating Temperature Conditions 32 to 122F (0 to 50C)
  • Approvals CE
  • Battery Backup Four AA Batteries (User Replaceable) Powers unit for up to 3 Days
  • Battery Life (Avg) 72 Hours (Back-up Only)
  • Calibration Options N100, N300, N400
  • Channels CH1: Temperature
  • Chart Rotation Speed 24 Hour, 7 Day or 31 Day
  • Dimensions 3.1 x 9.2 x 9.2in
  • Display Dimensions Height 1.375
  • Display Dimensions Width 2.0
  • Display Resolution 0.1
  • Display Type LCD
  • Enclosure Rugged Black ABS Case, Polycarbonate Door, Aluminum Dial
  • IP Rating 20
  • Included Accessories AC Adapter, Red Pen, Four AA Batteries, Replaceable Sensor, Quick Start Guide and 4' Bead-Wire Probe. *Charts sold separately.
  • Keypad Functions Power On/Off, Pen Home
  • Mounting Options Free Standing or Wall Mounted
  • Power Cord 6 ft
  • Power Source 120 to 240 VAC, 12 VDC (INTL fittings available); AC Adapter
  • Power Status Indicator LED Indicator
  • Remote Sensor Length 4
  • Remote Sensor Type 1 K T/C with Mini Connector
  • Response Time 30 Seconds to 63% of Full Scale
  • Temperature Accuracy +/-1.8F from -22 to 122F 3.8F (+/-1C from -30 to 50C 2.1C)
  • Temperature Range Help-50 to 50F/C; -20 to 20F/C; 0 to 100F/C; 0 to 150F/C; 0 to 250F/C; 0 to 500F/C; 0 to 1000F/C (0 to 2000F); 50 to 150F/C
  • Temperature Sensor Remote K-Thermocouple Probe with Replaceable Sensor
  • Unit Weight 9 lbs
  • Units/Pkg 1
  • Warranty 12-Month Limited
Why should I calibrate?

All instruments lose accuracy over time due to normal usage and the environmental conditions to which they are exposed.

How often should I calibrate?

For most applications, the recommended calibration interval is every twelve months.

N100 1-Point NIST Traceable Calibration $99.00 Add
N300 3-Point NIST Traceable Calibration $156.00 Add
N400 3-Point Ultima NIST A2LA Accredited Calibration $269.00 Add
What is NIST Calibration?

NIST stands for the National Institute for Standards and Technology. This organization is responsible for maintaining the master for different measurements, such as the standard "foot", standard, "second", or standard "pound". NIST also maintains the standard for temperature, humidity and pressure.

NIST Traceable means that the measuring standard can be traced directly back to the master standard maintained by the NIST organization.

NIST-Traceable does not tell you the measurement accuracy of a metrologty service in any detail. Only metrology services that can document their ISO 17025 standard provided data on their best measurement uncertainty.

$44.00
Sensor Dust Filter

Sensor Dust Filter - prolong the life of your sensor.

$110.00
Replaceable Sensor

Single K-TC Replaceable Temperature Sensor

$15.00
AC Adapter Extension Cable

10' Power Extension for R157 AC Adapter

$32.00
Universal Plug Kit for Data Loggers

International Plug Kit for Data Loggers

$32.00
Replacement AC Adapter

AC Adapter for TSB/TWE/TWP Loggers and the KT8/KT6 series.

$41.00
Temperature Probe

Replacement Bead Wire Temperature Probe

$125.00
Temperature Probe

6" (15cm) High Temperature Immersion Probe

$32.00
Glass Beads Bottle

Bottle of Glass Bead Solution - Dampen Temperature Swings.

$79.00
Piercing Probe

4" (10cm) Thermocouple Handled Piercing Probe

$156.00
Shielded Immersion Probe

15' (4.5m) Shielded Thermocouple with 4" (10cm) stainless steel tip

$52.00
Probe Extension

K-Thermocouple 10' (3m) Extension Cable

$179.00
Thermocouple Extension

K-Thermocouple 100' (30m) Extension Cable

C406 8" (203mm) Chart 31-Day, -50 to 50 $48.00 Add
C407 8" (203mm) Chart 31-Day, 0 to 250 F/C $48.00 Add
C408 8" (203mm) Chart 31-Day, 0 to 500 F/C $48.00 Add
C409 8" (203mm) Chart 31-Day, 0 to 100 F/C $48.00 Add
C410 8" (203mm) Chart 24-Hour, 0 to 100 $48.00 Add
C411 8" (203mm) Chart 24-Hour, -50 to 50 F/C $48.00 Add
C412 8" (203mm) Chart 7-Day, 0 to 100 $48.00 Add
C414 8" (203mm) Chart 7-Day, -50 to 50 F/C $48.00 Add
C425 8" (203mm) Chart 24-Hour, 0 to 150 or 0 to 0.15 F/C $48.00 Add
C428 8" (203mm) Chart 24-Hour, 0 to 500 F/C $48.00 Add
C429 8" (203mm) Chart 24-Hour, 0 to 60 $48.00 Add
C432 8" (203mm) Chart 24-Hour, 0 to 250 or 0 to 0.25 F/C $48.00 Add
C435 8" (203mm) Chart 7-Dday, 0 to 150 or 0 to 0.15 F/C $48.00 Add
C439 8" (203mm) Chart 7-Day, 0 to 250 or 0 to 0.25 F/C $48.00 Add
C440 8" (203mm) Chart 7-Day, 0 to 1000 F/C $48.00 Add
C441 8" (203mm) Chart 24-Hour, 0 to 1000 $48.00 Add
C443 8" (203mm) Chart 24-Hour, 0 to 2000 F $48.00 Add
C444 8" (203mm) Chart 7-Day, 0 to 2000 F $48.00 Add
C445 8" (203mm) Chart 24-Hour, -20 to 20 F/C $48.00 Add
C448 8" (203mm) Chart 7-Day, -20 to 20 F/C $48.00 Add
C459 8" (203mm) Chart 7-Day, 0 to 500 F/C $48.00 Add
P222 6 Red Pens $52.00 Add