Voltage Data Logger

Record inputs from any 0-20 mA or 0-5V transmitter for pH, flow, fluid level, or any variable you choose. This flexible data logger allows you to create your own recording instrument

  • 5-year battery life
  • 32,512 data point storage
  • User selectable 0-20mA or 0-5V
ES120
$249.00
Es120 front 859
Es120 rt angle 537
Es120 lft side 449
Es120 rt side 355
Es120 back 184
Es120 top 101

Download Images: Print Quality | Hi-Res


Important Information

DicksonWare Software is needed to communicate with this product and is sold separately.

Dickson Expert Services

Our Dickson Data Division has specially trained representatives to address the needs of customers with large installations or unique demands. Please call 888-452-4626.

Similar Products

ES120

ET855
Description 0-20 mA or 0-5V Voltage Data Logger 8" (203mm) Voltage Chart Recorder
Price $249.00 $659.00
Battery Operation Icon compare check
Compare Compare
Add to Cart Add to Cart
  • Accuracy - Recorder Only ±0.1
  • Allowed User Translatable Range -3200 to 3200
  • Ambient Operating RH Conditions 0-95% RH (non-condensing)
  • Ambient Operating Temperature Conditions -40 to 176F (-40 to 80C)
  • Approvals CE
  • Battery Life (Avg) 5 years
  • Channels 2 (1 current/1 voltage or 2 current or 2 voltage)
  • Data Capacity 32,000
  • Delayed Start Yes
  • Dimensions 3.1 x 2.1 x 0.9in (7.9 x 5.3 x 2.3cm)
  • IP Rating IP20
  • Input Connections Screw terminal block
  • Input Ranges 0 to 5V (1 to 5V); 0 to 20mA (4 to 20mA)
  • Key Features 5 Year Battery Life, 0 to 5 V, 0 to 20 mA, or 1 to 5 V
  • Minimum Software Version Required 6.0.3.0
  • Network Connectivity MP100
  • Output Range 0 to 5V (1 to 5V); 0 to 20mA (4 to 20mA)
  • Power Source 3V lithium coin cell battery (factory replaceable)
  • Power Status Indicator LED Indicator
  • Remote Sensor Type Sensor Capability: Any powered voltage or current transmitter with specified recorder input range
  • Resolution .001
  • Sample Interval Records data in configurable 10 second to 24 hour intervals, in 10 second increments.
  • Sample Storage Rate Storage rate until logger is full may vary, dependent upon selected Sample Interval.
  • Software Options A015
  • Unit Weight 1 lb; 2 oz; 56.7 g
  • Units of Measure User Defined Units Within DicksonWare Limited to 3276 max.
  • User Calibration with SW400 No
  • Warranty 12-Month Limited
$89.00
Software

DicksonWare Software with USB Cable

$69.00
USB Adapter

Serial to USB Adapter

$52.00
Case

Small Water-Resistant Pouch

$52.00
Wall Mount Case

Small Locking Wall Mount Case

$69.00
Software Upgrade

DicksonWare Software Upgrade

For more information on this product and other Voltage Data Logger products see the Voltage Data Logger page.

Frequently Asked Questions

  • Is the Data Logger functioning otherwise? Is the red L.E.D flashing? The L.E.D flashes once every 10 seconds and may be difficult to see in a well lit area.
  • Is the correct version of software being used?
    Minimum requirements are as follows:
    DicksonWare 6.0.3.0 or higher
  • Make sure the download cable is not physically defective.
  • Is the correct COM port selected?
  • Try all other available COM ports through the software.
  • Has the communication speed (baud rate) been changed? It should be set on ADAPTIVE. To check this, you must go to FILE, PREFERENCES, click the tab that says SERIAL or COMMUNICATIONS in the PREFERENCES window. Check the box for ADVANCED SERIAL OPTIONS then click OK. Now click LOGGER then COMMUNICATIONS, you'll see that SPEED is now one of your selections, click the SPEED tab to verify that it is set on ADAPTIVE.
  • Check Com port allocations in the PC's Device Manager, make sure the COM port you're trying to use is not "reserved" for something else.
  • Open the logger and depress the "RESET" button for about 5 seconds while still connected to the PC, then try all COM ports again.
  • Try another data logger. (if available)
  • Try another available COM port connection on back of PC.
  • If this is the first time attempting to communicate on this PC, or if new software or programs have been installed since the logger was last used, try installing the software on another PC.
    (not a laptop).
  • Is it possible that the logger was programmed to fill up storage space quicker than originally thought? Check the sample interval.
  • Is the logger set up to WRAP as opposed to STOP when full?
  • Make sure the "Input Signal" is set as follows, MIN 0, MAX 15. This setting must not be anything other than 0 MIN and 15 MAX! Set the "Range" to match your transmitter range.
  • Has the Data logger just been removed from a cool environment? Condensation may have momentarily formed internally, wait for the unit to warm up, it should power up and give all data stored.
  • Logger may not communicate at temperatures below 30 degrees F, although it will continue to log.
Voltage mode: 1 Meg
Current mode: 250 ohm

A USB to Serial adapter can be used. If you do not have an available dedicated serial port to use for communications with the logger, you may use a 3rd party USB to Serial adapter which is readily available from any electronic or computer store.

Setup: These adapters have a serial communications port and a USB communications port. The USB cable will connect to your computer and your existing serial cable will connect to the logger and the USB adapter. These adapters will also have a software driver that will need to be installed before use. Once the adapter is connected and the software installed, your computer will have a new serial port available under logger and communications.