Temperature & Humidity Logger

This product has been replaced by the TP125

The TX120 is an affordable, accurate and easy-to-use temperature and humidity data logger. Dickson's TX120 is compact, rugged and battery powered

  • Compact
  • Simple to use
  • Battery powered

Download Images: |

Important Information

DicksonWare Software is needed to communicate with this product and is sold separately.

Support Information
Support Information Dickson TX120 Product Manual
Dickson Expert Services
Support Information

Our Dickson Data Division has specially trained representatives to address the needs of customers with large installations or unique demands. Please call 888-452-4626.

Similar Products
Tp125-front-682
TP125
Tp425-front-741
TP425
Wh220-front-867
WH220
Sl4350-front-772
SL4350
Description Compact Temperature & Humidity Data Logger Compact Temperature & Humidity Logger with Display, Start/Stop Wireless Data Logger 4" (101mm) Portable, Battery Operated Temperature (-30 to 50C) Chart Recorder with Display
Price $199.00 $249.00 $229.00 $239.00
Display Icon-compare-check Icon-compare-check
Alarm Icon-compare-check
Battery Operation Icon-compare-check Icon-compare-check Icon-compare-check Icon-compare-check
Temperature Range Icon-question
  • -10 to 176F
    (-23 to 80C)
  • -4 to 158F
    (-20 to 70C)
  • -22 to 122F
    (-30 to 50C)
  • -22 to 122F
    (-30 to 50C)
Temperature Accuracy
  • ±0.8F from 20 to 120F 1.8F Remaining
    (±0.5C from -7 to 49C 1C Remaining)
  • ±0.8F from 20 to 120F 1.8F Remaining
    (±0.5C from -6 to 48C 1C Remaining)
  • ±0.8F from 20 to 122F 1.8F Remaining
    (±0.44C from -7 to 85C 1C Remaining)
  • ±2% from -22 to 122F
Humidity Range
  • 0-95% RH non-condensing
  • 0-95% RH non-condensing
  • 0-95% RH non-condensing
Humidity Accuracy
  • ±2% RH from 0 to 60%
  • ±3% RH from 60 to 95%
  • ±2% RH from 0 to 60%
  • ±3% RH from 60 to 95%
  • ±2% RH from 0 to 60%
  • ±3% RH from 60 to 95%
Compare Compare Compare Compare
Add to Cart Add to Cart Add to Cart Add to Cart
  • Unit Weight 1 lb
Why should I calibrate?

All instruments lose accuracy over time due to normal usage and the environmental conditions to which they are exposed.

How often should I calibrate?

For most applications, the recommended calibration interval is every twelve months.

N100 1-Point NIST Traceable Calibration $99.00 Add
What is NIST Calibration

NIST stands for the National Institute for Standards and Technology. This organization is responsible for maintaining the master for different measurements, such as the standard "foot", standard, "second", or standard "pound". NIST also maintains the standard for temperature, humidity and pressure.

NIST Traceable means that the measuring standard can be traced directly back to the master standard maintained by the NIST organization.

NIST-Traceable does not tell you the measurement accuracy of a metrologty service in any detail. Only metrology services that can document their ISO 17025 standard provided data on their best measurement uncertainty.

A015

$89.00

Software

DicksonWare Software with Serial Cable
Add to Cart

A060

$49.00

Serial Download Cable

Serial Download Cable - length 6 feet (2m)
Add to Cart

A100

$6.00

CR2032

3 Volt Lithium Coin Cell Battery
Add to Cart

A170

$69.00

USB Adapter

Serial to USB Adapter
Add to Cart

N520

$42.00

Certificate of Validation

Certificate of Validation
Add to Cart

A713

$52.00

Case

Small Water-Resistant Pouch
Add to Cart

A715

$52.00

Wall Mount Case

Small Locking Wall Mount Case
Add to Cart

SW701

$49.00

Software

DicksonWare Software Upgrade
Add to Cart

X025

$79.00

Cables

25' (7.625m) Serial Extension Download Cable
Add to Cart

X050

$90.00

Cables

50' (15.25m) Serial Extension Download Cable
Add to Cart

How do I replace the battery?

  1. Open the case by removing the screw on the back of the unit.
  2. Remove the battery from its holder by pressing hard on the battery holder tab. Replace the battery with a Lithium CR-2032 type; +side up.
  3. NOTE: The logger will stop sampling; however, memory will not be lost when replacing battery. To start sampling again download the data and then Clear Memory.

Why is the unit flashing red?

There is a LED indicator located on the front lower right corner of the unit. This indicator will flash red every 10 seconds ONLY when the unit is sampling and operating properly. If the indicator is not flashing, please verify the following:

The logger memory may be full; download the data and clear the memory.

Sampling may not be activated. To start sampling clear the memory.

Condensation may have formed on the unit. Place unit in a warm dry environment for 24 hrs.

Clear memory and try again. These loggers are designed for use in a non-condensing environment. If the environment creates condensation, try placing the unit (temperature only models) in a small sealed plastic bag to protect it from condensation.

Why won't the logger communicate?

Verify that you have the correct version of Dickson software installed on your PC. Version 10 or higher is required.

Verify that the correct port is selected: From the main Dicksonware screen, click on Logger then Communication, a black dot will appear next to the selected port. You may need to select a different port.

You may need to relocate the download cable to another USB port and possibly try changing the port again in DicksonWare.

If communication has not been established with the previous steps, you may need to open the logger and remove the battery for a few seconds and then try all ports and cable combinations again (this will not cause the unit to lose any logged data, but you will have to clear the logger to restart the logging process, this is done using DicksonWare).

If possible, try another PC