Temperature Data Logger

A small temperature data logger with lots of cool features - Start/Stop functionality for the most precise data collection needs along with a digital display that provides current and min/max readings.

  • Digital Display
  • Start & Stop button
  • 32KB data storage
  • Battery powered
Calibration Method

Calibration ensures Regulatory and Audit Compliance

SP425

$159.00

Important Information

DicksonWare Software is needed to communicate with this product and is sold separately.

Support Information
Support Information Dickson SP425 Product Manual
Dickson Expert Services
Support Information

Our Dickson Data Division has specially trained representatives to address the needs of customers with large installations or unique demands. Please call 888-452-4626.

Similar Products
Sp425-front-770
SP425
Ft500-front-home-872
FT500
Sm300-front-729
SM300
Wt200-front-848
WT200
Description Start & Stop, Digital Display Temperature Logger Temperature Touchscreen Data Logger with Large Display Wireless Data Logger
Price $159.00 $299.00 $249.00 $199.00
Display Icon-compare-check Icon-compare-check Icon-compare-check
Alarm Icon-compare-check Icon-compare-check
Battery Operation Icon-compare-check Icon-compare-check Icon-compare-check
Temperature Range Icon-question
  • -4 to 158F
    (-20 to 70C)
  • 0 to 122F
    (-18 to 50C)
  • -4 to 158F
    (-20 to 70C)
  • -22 to 122F
    (-30 to 50C)
Temperature Accuracy
  • ±1.2F from -4 to 158F
    (±0.7C from -20 to 70C)
  • ±1.2F from 0 to 122F
    (±0.7C from -18 to 50C)
  • ±0.8F from 20 to 120F 1.8F
    (±0.5C from -7 to 49C 1C)
  • ±1.2F from 20 to 122F 1.8F
    (±1C from -30 to 50C)
Compare Compare Compare Compare
Add to Cart Add to Cart Add to Cart Add to Cart
  • Ambient Operating RH Conditions 0-95% RH non-condensing
  • Ambient Operating Temperature Conditions -4 to 158F (-20 to 70C)
  • Battery Life (Avg) 1 Year
  • Cable Details USB - Male Series A plug to 5 pin Male Series B mini plug.
  • Cable Length 6ft
  • Calibration Options N100, N300, N400, N520
  • Channels CH1: Temperature
  • Data Capacity 32,512
  • Dimensions 2.25 x 38 x 1.34in
  • Display Resolution 1
  • Display Type LCD
  • Display Update Rate 20 Seconds
  • Download Time 1 Minute
  • Download Type USB
  • IP Rating 20
  • Included Accessories 123A Lithium Battery and Quick Start Guide. *Software is not included.
  • Minimum Software Version Required 13.6
  • PC Requirements Microsoft Windows 98 or higher; 16 MB RAM, 1 free USB root hub, CD drive, VGA monitor or better
  • Power Source 132A Lithium Battery (User Replaceable)
  • Sample Interval User Selectable (from 1 second to 24 hour intervals, in 1 second increments).
  • Software Options A016, A026
  • Temperature Accuracy +/-1.2F from -4 to 158F (+/-0.7C from -20 to 70C)
  • Temperature Range Icon-question -4 to 158F (-20 to 70C)
  • Temperature Sensor Type Internal Digital Temperature Sensor
  • Unit Weight 1 lb
  • Units/Pkg 1
  • Warranty 12 Month Limited
Why should I calibrate?

All instruments lose accuracy over time due to normal usage and the environmental conditions to which they are exposed.

How often should I calibrate?

For most applications, the recommended calibration interval is every twelve months.

N100 1-Point NIST Traceable Calibration $99.00 Add
N300 3-Point NIST Traceable Calibration $156.00 Add
N400 3-Point Ultima NIST A2LA Accredited Calibration $269.00 Add
What is NIST Calibration

NIST stands for the National Institute for Standards and Technology. This organization is responsible for maintaining the master for different measurements, such as the standard "foot", standard, "second", or standard "pound". NIST also maintains the standard for temperature, humidity and pressure.

NIST Traceable means that the measuring standard can be traced directly back to the master standard maintained by the NIST organization.

NIST-Traceable does not tell you the measurement accuracy of a metrologty service in any detail. Only metrology services that can document their ISO 17025 standard provided data on their best measurement uncertainty.

A016

$89.00

Software

DicksonWare Software with USB Cable
Add to Cart

A026

$199.00

Software

DicksonWare Secure Software with USB Cable
Add to Cart

A061

$49.00

USB Download Cable

USB Download Cable - length 6 feet (2m)
Add to Cart

A125

$13.00

123A Battery

3 Volt Lithium Battery
Add to Cart

N520

$42.00

Certificate of Validation

Certificate of Validation
Add to Cart

A715

$52.00

Wall Mount Case

Small Locking Wall Mount Case
Add to Cart

SW400

$249.00

Software

Logger Calibration Software
Add to Cart

Why won''t the logger communicate?

Verify that you have the correct version of Dickson software installed on your PC. Version 13.6 or higher is required.

 

  • Verify that USB is the selected port
  •  

  • You may need to relocate the download cable to another USB port and possibly try changing the port again in DicksonWare.
  •  

  • If communication has not been established with the previous steps, you may need to open the logger and remove the battery for a few seconds and then try all ports and cable combinations again (this will not cause the unit to lose any logged data, but you will have to clear the logger to restart the logging process, this is done using DicksonWare).
  •  

  • If possible, try another PC
  • How do you change the display between F and C?

    Within the software under "setup" and "display".

    Why does the downloaded data show a future date?

    The logger may not have been cleared prior to use. Please clear the logger before placing the unit in service.

    Why is the display blank?

    Untitled Document
    • The display will remain blank if Press to Start is selected in Setup, but logging has not yet begun. Hold down the start button on the front of the logger for 1 second to start logging.

    Why won't the logger communicate?

    Verify that you have the correct version of Dickson software installed on your PC. Version 10 or higher is required.

    Verify that the correct port is selected: From the main Dicksonware screen, click on Logger then Communication, a black dot will appear next to the selected port. You may need to select a different port.

    You may need to relocate the download cable to another USB port and possibly try changing the port again in DicksonWare.

    If communication has not been established with the previous steps, you may need to open the logger and remove the battery for a few seconds and then try all ports and cable combinations again (this will not cause the unit to lose any logged data, but you will have to clear the logger to restart the logging process, this is done using DicksonWare).

    If possible, try another PC