Phone Orders: 1-800-757-3747

Ethernet-Connect Temperature & Humidity
Data Logger

Manage all the data loggers in your network from one PC - connecting data loggers to your Ethernet network is as easy as installing a printer!
Time-saving Data Management features-
• 24/7 feedback through Min/Max or Real-Time Display
• Visual/audio alarms
• Email alert capable


TM725

$599.00 USD

Add to Cart

TM725 with 1-Point NIST Calibration (N100)

$698.00 USD

Add to Cart

Model # Network Connectivity Remote Probe Temp. Accuracy Temperature Range Price
TM325 MP100 Yes 0.8F
0.5C
-40 to 185F
-40 to 85C
$399.00 Add to Cart
TM320 MP100 0.8F
0.5C
-4 to 158F
-20 to 70C
$299.00 Add to Cart
TM725 Ethernet Yes 0.8F
0.5C
-40 to 185F
-40 to 85C
$599.00 Add to Cart
Humidity Range:

0 - 95% RH

Humidity Sensor:

Monolithic IC Humidity Sensor

Humidity Accuracy:

±2% RH @ 77°F (25°C)

Remote Temperature Range:

-40 to +185°F (-40 to +85°C)

Temperature Sensor:

Thermistor

Temperature Accuracy:

±0.8F (±.5C) for a temperature between +20 to +120F (-7 to +49C) ; ±1.8F (±1C) for all other temperaure ranges

Dew Point Range (Calculated):

-22 to +122°F (-30 to +50°C)

Dew Point Accuracy (Calculated):

±3.6°F (±2°C) from 30 to 95% RH

Ambient Operating Conditions:

-4 to +158°F (-20 to +70°C); 0 to 95% RH non -condensing

Download Type:

USB, Serial or Standard Ethernet

Download Time:

1 Minute (USB); 3 Minutes (Serial); 2.0 Minutes (Ethernet)

Keypad Functions:

3 buttons with tactile feedback; Min/Max, Alarm, Save

Response Time:

1 minute to 63% of full scale, typical

Display:

Medium

Display Update Rate:

10 Seconds under battery power; 1 second under AC power.

Display Dimensions:

2.0" x 1.375"

Display Min/Max:

Yes

Resolution:

0.1° From 0.0 to 999.9; 1° over 1000

Power Source:

Battery (included/backup only), 1 9V; AC adapter (included)-(Input Voltage/Current: 120VAC/60Hz/16W; Output Voltage/Current: 9VDC/1A; Optional Universal International Adapter available

Power Status Indicator:

LCD Display

Input Connections:

Plugs directly into outlet; Output Connection: 3.5mm stereo plug; Length: 6 feet)

Battery Life (Avg):

1 month

Battery Backup:

Yes with AC Adapter

Memory:

EEPROM

Data Capacity:

32000
16-bit Samples

Sample Interval:

Records data in configurable 1 second to 24 hour intervals, in 1 or 10 second increments.

Sample Storage Rate:

Storage rate until logger is full may vary, dependent upon selected Sample Interval.

Alarm:

Audio/Visual

Approvals:

CE

Calibration:

Standard Dickson Certificate of Calibration

User Calibration w/ SW400:

Yes

Available Calibration Options:

User: zero point, Factory: NIST traceable

Enclosure:

Polycarbonate

Mounting:

Wall mountable via keyhole slots

Remote Probe Dimensions:

Houses thermistor and RH sensor in polycarbonate plastic; 5.9" x 0.91" (15cm x 2.3cm); Cable Length: 6’ (2 meters)

Included Accessories:

Battery, instruction manual, AC Adapter

DicksonWare™ Software Minimum Version Required:

9.0 DicksonWare Secure Software Required

DicksonWare™ PC/Software Requirements:

Windows® 98, 2000, and XP; PC with 486 MHz or better microprocessor, 16MB RAM, 1 free COM (serial) port with dedicated interrupt or 1 USB root hub, CD drive, VGA monitor or better

DicksonWare™ Cable Type/Length:

A025: 9 pin female D-shell to male 2.5mm stereo plug, 6 feet; A026: USB male series “A” plug to 5-pin male series “B” mini plug, 6’ (2 meters)

DicksonWare™ Computer Interface:

RS-232 serial (COM) port or USB

Units / Pkg:

1

Dimensions (Inches/cm):

4.0x3.0x1.6
10.2x7.7x3.9

Weight:

9 oz

IP Rating:

IP20

Warranty:

12 Month Limited

Key Features:

1.High/Low Alarm 2.Min/Max Display 3.High Speed USB Connectivity & Flash Memory

A.K.A.:

Data Logger, Midsize Display Data Logger, Midsize Display Logger, USB Logger, Dickson Data Logger, Dickson Display Logger, Dickson TM, Datalogger, Temperature and Humidity Data Logger, Memory Card, Alarm, Digital Display Logger, Temperature and Humidity Logger, Data Environment Logger, Flash Memory Card, Alarm, Remote Probe Data Logger, Remote Probe Logger, Two Channel Data Logger, Temperature Humidity Data Logger, Datalogger, Ethernet Connectivity, Network, Ethernet Data Logger

Remote Probe:

Yes

Network Connectivity:

Ethernet

Temperature Range:

-40 to 185F
-40 to 85C

SD Memory Card:

Yes

RH Accuracy:

±2%

Temp. Accuracy:

0.8F
0.5C

Power:

Battery

Qty. Model # Description Price
N100 NIST Traceable Calibration 1-pt. (Per New Unit) $99.00
N300 NIST Traceable Calibration 3-pt. (New Unit) $156.00
N400 A2LA Accredited Calibration 3-pt. (New Unit) $269.00
N520 Certificate of Validation $42.00
Qty. Model # Description Price
A025 DicksonWare™ SECURE Software and Serial Download Cable (21CFR11 compliant) Version 12.4 $199.00
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11 compliant) Version 12.4 $199.00
SW400 Logger Calibration Software $249.00
R157 AC Adapter $32.00
A060 Serial Download Cable Only $49.00
A061 USB Download Cable Only $49.00
A870 7' Network Cable (category 5 ethernet cable) $16.00
A871 25' Network Cable (category 5 ethernet cable) $32.00
R007 9V Battery $11.00
R065 Universal International AC Adapter $32.00
A029 DicksonWare™ SECURE Software with Email Notification and USB Download Cable (21CFR11 compliant) Version 12.4

For use with Models SM720, SM725 and TM725

$219.00
A867 Probe Dust Filter $32.00