Phone Orders: 1-800-757-3747

Time-Saver RTD Probe Temperature Data Logger

High Accuracy RTD Probe-- designed for pharmaceutical FDA compliance and other demanding applications.
Time-saving Data Management features-
• 24/7 feedback through Min/Max or Real-Time Display with visual/audio alarms
• USB-enabled triple-speed data downloading
• FLASH memory card data transfer-capable
• +/-0.5F accuracy with RTD Probe


SM420

$499.00 USD

Add to Cart

SM420 with 1-Point NIST Calibration (N100)

$598.00 USD

Add to Cart

Model # Network Connectivity Temp. Accuracy Temperature Range Remote Probe Price
SM300 MP100 0.8F
0.5C
-4 to 158F
-20 to 70C
$249.00 Add to Cart
SM320 MP100 1.8F
1.0C
Internal:
-4 to 158F
-20 to 70C
Remote:
-300 to +2000°F
(-184 to +1093°C)
Yes $299.00 Add to Cart
SM325 MP100 1.8F
1.0C
-300 to 2000F
-184 to 1093C
Yes(2) $399.00 Add to Cart
SM420 MP100 0.5F
0.3C
-50 to 350F
-45 to 176C
Yes $499.00 Add to Cart
SM720 Ethernet 1.8F
1.0C
-300 to 2000F
-184 to 1093C
Yes $549.00 Add to Cart
SM725 Ethernet 1.8F
1.0C
-300 to 2000F
-184 to 1093C
Yes(2) $599.00 Add to Cart
Remote Temperature Range:

Range with standard PRTD Probe: -50 to +350°F (-45 to +176°C)

Remote Sensor:

Platinum RTD w/6 ft. cable length and 2 inch stainless steel tip

Remote Temperature Accuracy:

±0.5°F (±0.28°C)

Ambient Operating Conditions:

-4 to 158F (-20 to 70C); 0 to 95% RH non -condensing

Download Type:

USB, Serial or Memory Card

Download Time:

1 Minute (USB); 3 Minutes (Serial)

Keypad Functions:

3 buttons with tactile feedback; Min/Max, Alarm, Download

Response Time:

3 minutes typical

Display:

Medium

Display Update Rate:

10 Seconds under battery power; 1 second under AC power.

Display Dimensions:

2.0" x 1.375"

Display Min/Max:

Yes

Resolution:

0.1° From 0.0 to 999.9; 1° over 1000

Power Source:

Batteries, 4 AA Alkaline; AC adapter - optional (Input Voltage/Current: 120VAC/60Hz/16W; Output Voltage/Current: 9VDC/1A

Power Status Indicator:

LCD Display

Input Connections:

Plugs directly into outlet; Output Connection: 3.5mm stereo plug; Length: 6 feet)

Battery Life (Avg):

6 months

Battery Backup:

Yes with optional AC Adapter

Memory:

EEPROM, Removable Flash Storage Device - stores data from 1000+ Data Loggers

Data Capacity:

32000
16-bit Samples

Sample Interval:

Records data in configurable 1 second to 24 hour intervals, in 1 or 10 second increments.

Sample Storage Rate:

Storage rate until logger is full may vary, dependent upon selected Sample Interval.

Alarm:

Audio/Visual

Approvals:

CE

Calibration:

Standard Dickson Certificate of Calibration

Available Calibration Options:

User: zero point, Factory: NIST traceable

User Calibration w/ SW400:

Yes

Enclosure:

Polycarbonate

Mounting:

Wall mountable via keyhole slots

Included Accessories:

Batteries, instruction manual

DicksonWare™ Software Minimum Version Required:

9.0

DicksonWare™ PC/Software Requirements:

Windows® 98, 2000, and XP; PC with 486 MHz or faster microprocessor, 16MB RAM, 1 free COM (serial) port with dedicated interrupt or 1 USB root hub, CD drive, VGA monitor or better

DicksonWare™ Cable Type/Length:

A015/A025: 9 pin female D-shell to male 2.5mm stereo plug, 6 feet; A016/A026: USB male series “A” plug to 5-pin male series “B” mini plug, 6 ’ (2 meters)

DicksonWare™ Computer Interface:

RS-232 serial (COM) port or USB

Units / Pkg:

1

Dimensions (Inches/cm):

4.0x3.0x1.6
10.2x7.7x3.9

Weight:

9 oz

IP Rating:

IP20

Warranty:

12 Month Limited

Key Features:

1.High/Low Alarm
2.Min/Max Display
3.High Speed USB Connectivity & Flash Memory

A.K.A.:

Data Logger, Computers, Hardware, Test Equipment, Midsize Display Data Logger, Midsize Display Logger, USB Logger, Dickson Data Logger, Dickson Display Logger, Dickson SM, Datalogger, Temperature Data Logger, Memory Card, Alarm, Digital Display Logger, Temperature Logger, Data Environment Logger, Flash Memory Card, Alarm, K-Thermocouple Data Logger, K-TC Data Logger, Remote Probe Data Logger, Remote Probe Logger, Thermocouple Data Logger, High Temperature Data Logger, Two Channel Data Logger, Datalogger, Platinum RTD

Remote Probe:

Yes

Remote Sensing Range:

-50 to +350°F

Temperature Accuracy:

±0.5F
±0.28C)

Temperature Range:

-50 to 350F
-45 to 176C

Network Connectivity:

MP100

Temp. Accuracy:

0.5F
0.3C

SD Memory Card:

Yes

Power:

Battery

Remote Probe Dimensions:

Metal tip: 2 inch length, .190 inch diameter; Cable: 6 foot length, .110 diameter

Qty. Model # Description Price
N100 NIST Traceable Calibration 1-pt. (Per New Unit) $99.00
N300 NIST Traceable Calibration 3-pt. (New Unit) $156.00
N400 A2LA Accredited Calibration 3-pt. (New Unit) $269.00
N520 Certificate of Validation $42.00
Qty. Model # Description Price
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11 compliant) Version 12.4 $199.00
A025 DicksonWare™ SECURE Software and Serial Download Cable (21CFR11 compliant) Version 12.4 $199.00
A016 DicksonWare™ Software
USB Download Cable
Version 12.4
$79.00
A015 DicksonWare™ Software
Serial Download Cable
Version 12.4
$79.00
A060 Serial Download Cable Only $49.00
A061 USB Download Cable Only $49.00
A210 Removeable FLASH Storage Device $83.00
A220 Card Reader Kit - Includes USB Memory Card Reader and One Flash Memory Card. $135.00
R157 AC Adapter $32.00
SW400 Logger Calibration Software $249.00
R006 "AA" Alkaline battery $6.00
R065 Universal International AC Adapter $32.00