Documents On/Off Cycle Patterns - for pumps, chillers, conveyors, processing equipment and more…
Monitors On/Off events in wide range of real-world applications--
• 120V – 240V AC Parallel operation
• 1 Year battery life
• 65,512 Sample point storage
• Compact, rugged design
| Model # | Event Range | Price | |
|---|---|---|---|
| EV100 | On and Off events from 120V to 240V | $299.00 | Add to Cart |
On and Off events from 120V to 240V
Maximum Input Voltage:120 to 240V AC parallel operation
Input Connections:Alligator clips with 5’ cord (included)
Channels:One
Ambient Operating Conditions:-22 to +185°F (-30 to +85°C), 0 to 95% RH (non-condensing)
Data Capacity:65512
Sample Interval:Records data in configurable 10 second to 24 hour intervals, in 10 second increments.
Sample Storage Rate:Storage rate until logger is full may vary, dependent upon selected Sample Interval.
Power Source:3V lithium coin cell battery (User replaceable)
Battery Life (Avg):1-year
Power Status Indicator:LED Indicator
Approvals:CE
Software Required:A015
DicksonWare™ Software Minimum Version Required:7.2
DicksonWare™ PC/Software Requirements:Microsoft Windows® 95, 98, 2000, NT or XP; PC w/ 386 MHz or faster microprocessor, 4 MB RAM, 1 free COM (serial) port, CD drive
DicksonWare™ Cable Type/Length:9 pin male D-shell to male 2.5mm stereo plug, 6’ long
DicksonWare™ Computer Interface:RS-232 COM (serial) port
Dimensions (Inches/cm):3.1x2.1x0.9
7.9x5.3x2.3
IP20
Warranty:12-Month Limited
Key Features:1.1 Year Battery Life
2.Monitor On/Off Events from 120V to 240V AC Parallel
Data Logger, Computers, Hardware, Test Equipment, Dickson Event Data Logger, Dickson EV Logger, Datalogger, Event Data Logger, Dickson On/Off Event Data Logger, Datalogger
Network Connectivity:MP100
Power:Battery
| Manual: | EV100 Web Manual.pdf |